Refurbished Manufacturer Number: S30810-Q2150-X-11 The SLMB (Station Line Module with Burst System) board for burst signaling systems (U200 interface) is used for connecting digital terminals and the attendant console AC.
The lines are monitored, and the module is blocked if a fault occurs.
Refurbished Manufacturer Number: S30810-Q2260-X
The card DM4L (Data Processor Mono 486 with LAN) covers the same functionality as the card DM3L but brings higher performance to the systems 310E and 350E.
Although being software compatible there are slight differences in the non-volatile memory and the card's internal initialization which can be handled during system boot.
Refurbished Manufacturer Number: S30810-Q2260-X100
The card DM4L (Data Processor Mono 486 with LAN) covers the same functionality as the card DM3L but brings higher performance to the systems 310E and 350E. Although being software compatible there are slight differences in the non-volatile memory and the card's internal initialization which can be handled during system boot.
Refurbished Manufacturer Number: S30810-Q2136-X000-16 The Stream Control Central board SCC for Hicom 300/300E, is the interface between the central Processor DM80 and the peripheral boards of the Hicom 3X3.
Functions of the board are:
•Clock generator SCG (Small Clock Generator) •DCL (Data Communication Link) •Switching network MTS (Memory Time Switch) •Switching network MTS (Memory Time Switch) •LTUC sub-functions (Line Trunk Unit Controller) •SIUCO functions (Signaling Unit and Conference)
Refurbished Manufacturer Number: S30810-Q2136-X-P4 The Stream Control Central board SCC for Hicom 300/300E, is the interface between the central Processor DM80 and the peripheral boards of the Hicom 3X3.
Refurbished Manufacturer Number: S30810-Q2136-X-09
The Stream Control Central board SCC for Hicom 300/300E, is the interface between the central Processor DM80 and the peripheral boards of the Hicom 3X3. Functions of the board are:•Clock generator SCG (Small Clock Generator)
Refurbished Manufacturer Part Number: S30810-Q2163-X000-09
The STMD2 (Station/Trunk Module Digital S0+SLMS2 Station Line Module Digital S0) board comprises the STMD and SLMS function on one single board. The STMD2 covers all features which are provided by the replaced modules. It contains eight trunks with S0 interfaces. Each S0 connection (4-wire-system) constitutes a basic access with two B-channels (64 kbits/s each) for speech/data and a D-channel (16 kbits/s).
Description of STMD/SLMS modul:
Refurbished Manufacturer Part Number: S30810-Q2025-X300
The TMBD (Trunk Module "Bundespost Deutschland") (4 circuits per module) can be used for signalling with main station interfaces (MOSIG) as well as for direct inward dialing with the pulse signalling system.
In both cases, one-way as well as bothway operation with or without 16 kHz call charge registration is possible.
The operating mode is set using circuit data. The individual circuits on the board can thus be operated in different modes.
There are three DIP-FIX switches per circuit on the board which allow setting of call data registration and line attenuation levels. The board has a separate blocking key for each circuit.
The front panel of the board contains 4 LEDs and 4 disable keys.
Refurbished Manufacturer Part Number: S30810-Q2151-X300
The SLC16 (Subscriber Line Cordless) board is usable in all hardware plattforms of the Hicom 300E as of Version 1.0. The board allows for the connection of 16 cordless base stations.
Refurbished S30810-Q2180-X000-03
Refurbished Herstellernummer: S30810-Q2064-X100-04 Siemens TMLR
Refurbished Manufacturer Part Number: S30810-Q2167-X000-10
Siemens TMAS 8
Refurbished Manufacturer Part Number: S30810-Q2230-X
The DM3L (Data Processor Mono 386 with LAN-Interface) board for Hicom 300/300E, is divided into three blocks according to function. The main processor unifies the functionality of the DP and IOPA modules. A 386DX microprocessor with 50MHz clock frequency (25 MHz processor bus frequency) is used as the CPU. This microprocessor has access to a local bus and to the system bus. On-board I/O ports and memory, local memory and the SCSI and LAN controllers with their I/O ports are connected to the local bus. The V.24 block comprises the LCU function. Its control can be assumed either by the 386DX via the local bus, or by the signal processor configurable by software.
With the SCSI interface the DM3L connects to external bulk data storage systems. The LAN node forms a high speed interface to other modules and off-system components.
Refurbished Manufacturer Part Number: S30810-Q2924-X
Siemens CONBO Connection board
Refurbished Manufacturer Part Number: S30810-Q2901-X000
The SLMO (Subscriber Line Module Cost Optimized UP0/E) board offers connections for the connection of optiset E- and optiPoint 500 devices to the HiPath 3750, HiPath 3550 and HiPath 3700.
Refurbished Manufacturer Part Number: S30810-Q2936-X000, L30251-U600-G226
The CBCPR board handles the central control and switching operations of the the HiPath 3750 and HiPath 3700.
Refurbished Manufacturer Part Number: S30810-Q2558-X200
The Station/Trunk Module Digital S0 (STMD8) for Hicom 150E OfficePro /Com and Hipath 3750/ 3700, unites the functions of the TMD- and SLMS- boards. It has 8 sets with S0-Interface.
Refurbished Manufacturer Part Number: S30810-Q2940-X000
HiPath Hicom HG 1500 IP-Gateway HXGM 2 board The HXGM2 module S30810-Q2940-X is the Voice and Data Unit for HiPath 3000 and allows the connection between HiPath 3000 and a LAN environment.
Refurbished Manufacturer Part Number: L30251-U600-A599, S30810-Q2225-X100
The modules SLMAE8 (Subscriber Line Module Analog Enhanced) represent analog a / b interfaces for use in HiPath 3800 V6.0 SMR-10 is available:
SLMAE8 (S30810-Q2225-X100) = 8 analog a / b interfaces
Refurbished Manufacturer Part Number: S30810-Q2190-X
The LBU (Line Control / Line Bus Control) board for Hicom 300E offers two V.24 interfaces on the front panel for connecting terminals and/or data processing systems. In addition, the board links active peripheral boards with the DP multibus for configuring the service modules.
The two functional units are entirely separate, so that the line control and line bus control can be operated separately or together, at the appropriate slots. The operating mode decoder of the LBU determines the operating mode according to the occupied slot. The front panel of the board contains 3 LEDs (RUN, H2, H3), 1 INT-key and 2 V.24 interfaces.
{{.}}
{{{.}}}