Refurbished Manufacturer Part Number: S30810-Q2817
TRIMY HiPath Trading Workplace
Refurbished S30810-Q2143-X-02 The hub controller (HUBC) board is required to support the local area network (LAN) in all HiPath 4500 configurations. This board provides the physical link between the administration and data processor (ADP), active switching unit (SWU), and standby SWU. The HUBC board is a centralized wiring hub for the twisted pair Ethernet star topology. It is controlled by the ADP. The HUBC board provides basic Ethernet management. The ADP uses free I/O addresses to access the HUBC board through the multibus 1 interface. The ADP reads the HUBC board port status information and disables ports if necessary. The ADP writes the link status for the eight twisted pair ports to the HUBC board LED register, providing the port status LED indications. The HUBC board is installed in slot 25 and controlled by the ADP (DPC5 in slot 31).
Refurbished Manufacturer Part Number: S30810-Q2143-X000-02
The hub controller (HUBC) board is required to support the local area network (LAN) in all HiPath 4500 configurations. This board provides the physical link between the administration and data processor (ADP), active switching unit (SWU), and standby SWU. The HUBC board is a centralized wiring hub for the twisted pair Ethernet star topology. It is controlled by the ADP.
The HUBC board provides basic Ethernet management. The ADP uses free I/O addresses to access the HUBC board through the multibus 1 interface. The ADP reads the HUBC board port status information and disables ports if necessary. The ADP writes the link status for the eight twisted pair ports to the HUBC board LED register, providing the port status LED indications. The HUBC board is installed in slot 25 and controlled by the ADP (DPC5 in slot 31).
Refurbished Manufacturer Part Number: S30810-Q2930-X100
HXGM HG 1500 S30810-Q2930-X100
Refurbished Manufacturer Part Number: S30810-Q2940-X000
HiPath Hicom HG 1500 IP-Gateway HXGM 2 board The HXGM2 module S30810-Q2940-X is the Voice and Data Unit for HiPath 3000 and allows the connection between HiPath 3000 and a LAN environment.
Refurbished Manufacturer Part Number: S30810-Q2942-X
Connection of a local LAN to the HiPath 3000 and connection with external LANs over the ISDN and DSL interfaces of the HiPath 3000
The HXGM3 board prepares the functions of the HiPath HG1500 Version 3.0 for the HiPath 3750 and HiPath 3700. Connection of a local LAN to the HiPath 3000 and connection with external LANs over the ISDN and DSL interfaces of the HiPath 3000 Support of the conventional functions of ISDN and DSL Routers with the additional functions of a media gateway for the transmission of voice, fax, and data. Forwarding of conversations between IP based networks (LAN, Intranet, Internet) and circuit switched networkes (ISDN, PSTN)
The HXGM3 board is compatible to the HiPath HG 1500 V2.0 board HXGM2. A mixed installation of both boards in a system is possible.
Refurbished Manufacturer Part Number: S30810-Q2943-X
HiPath HXGS3 HG 1500 V3.0 for HiPath 3350/3550 with 2 slots for expansion modules
Refurbished Manufacturer Part Number: S30810-Q2190-X
The LBU (Line Control / Line Bus Control) board for Hicom 300E offers two V.24 interfaces on the front panel for connecting terminals and/or data processing systems. In addition, the board links active peripheral boards with the DP multibus for configuring the service modules.
The two functional units are entirely separate, so that the line control and line bus control can be operated separately or together, at the appropriate slots. The operating mode decoder of the LBU determines the operating mode according to the occupied slot. The front panel of the board contains 3 LEDs (RUN, H2, H3), 1 INT-key and 2 V.24 interfaces.
Refurbished Manufacturer Part Number: S30810-Q2128-X
The LTUC-module board S30810-Q2128-X (Line Trunk Unit Control) for the Hicom 300 & Hicom 300E which constitutes the interface between the transducer for the signaling-channel DCL, the crossbar switch CN and the peripheral BG of the LTU-frame.
This board implements the switchover from redundant central sytem units to the non-redundant periphery and the electrical conversion and decoupling. In the LTUC, the lines for the speech channels, signaling channels, clock lines and reset signals are converted from balanced to imbalanced signals and transferred from the currently active control to the peripheral board with the shelf, and vice versa.
Compatible only with the following system:
Refurbished Manufacturer Part Number: S30810-Q2248-X
The LTUCE (Line Trunk Unit Control Extended) is the interface between central and peripheral parts of the system. It has an interface to the MTSCG /SICOE and the QDCL boards of both common controls. The transmission mode to and from the common control is balanced. On the peripheral part the LTUCE has an interface to all boards in the shelf with an unbalanced transmission mode. The LTUCE selects the signals from the active common control and distributes them in the LTU-Shelf (LTU-Shelf is a general expression for the peripheral-shelf. It can be one of the compact- or extended compact-shelf). The LTUCE also receives signals from the peripheral boards and transmits them to the common control.
The front panel of the module contains one red and one green LED.
Refurbished Manufacturer Part Number: S30810-Q2248-X000
The LTUCE (Line Trunk Unit Control Extended) is the interface between central and peripheral parts of the system. It has an interface to the MTSCG /SICOE and the QDCL boards of both common controls. The transmission mode to and from the common control is balanced. On the peripheral part the LTUCE has an interface to all boards in the shelf with an unbalanced transmission mode.
The LTUCE selects the signals from the active common control and distributes them in the LTU-Shelf (LTU-Shelf is a general expression for the peripheral-shelf. It can be one of the compact- or extended compact-shelf). The LTUCE also receives signals from the peripheral boards and transmits them to the common control.
Refurbished Manufacturer Part Number: S30810-Q2166-X
LTUCX; Line Trunk Unit Control Extended
The line trunk unit control extended (LTUCX) board has twice the number of speech highways as in the former LTUCE board. It is supported for a standard LTU shelf by adding new 2x4x2 MB highways to the already existing 2x4x2 megabit highways. As an LTU shelf is devided into two shelf halfs, each shelf half supports 128TSL of bundle A and 128TSL of bundle F.
The additional speech highways can only be used by boards which support this feature (for example the DIU-N2 and DIU-N4 boards). Within the board configuration it is determined if the board uses the standard speech highways or the additional ones. Simultaneous use of all highways is not supported with this feature.
You can now use a few new boards (to access additional highways; reservation of many TSLs for every board; for example, DIU-N4 = 128 TSL) with a greater number of old boards (only access to the standard highways; reservation of few TSLs per board) together in the same shelf in a non blocking configuration.
Compatible:
Refurbished Manufacturer Part Number: S30810-Q2166-X000
Refurbished Manufacturer Part Number: S30810-Q2224-X
The MTSCG (Memory Time Switch and Clock Generator) board is a central board. It integrates the functionality of an MTS64 or MTS128 (Memory Time Switch) and an NCG (Network Clock Generator). So it contains both functions, the function of Highways switching aswell as the clock functions for the system (supply and synchronization to an external or internal reference clock). Regarding clocks and highways the MTSCG fullfils the same timing conditions.
Refurbished Manufacturer Part Number: S30810-Q2224-X000
Refurbished Manufacturer Part Number: S30810-Q2224-X001
Refurbished Manufacturer Part Number: S30810-Q2029-X100
PCG Peripheral Clock Generator
The PCG-module S30810-Q2029-X100 (Peripheral Clock Generator) for Hicom 300 / 300E is the clock for the operated synchronously Hicomsystem.
features:
Use in: Hicom 300
Refurbished S30810-Q2139-X-05 The function of the PSIO is to provide a total of six V.24 interfaces having enhanced functionality and higher data rates.
A Hicom 3X3 can accomodate a maximum of 2 PSIO boards (12 V.24 interfaces). Max 2 PSIO can be installed in the CC80 or CC80W shelf, in slots 61 and 73 (special slots). The PSIO board is connected to the SCC module via an HDLC channel. The board is connected via a so-called "Hydra" cable (cable plug in the panel of the Hicom 3X3 has 4 cable outlets and V.24 interfaces). For CC80 shelves, the PSIO board may only be plugged into slot 60). In all other cases, it can be plugged into any peripheral slot available. The module must be configured by means of AMOs BCSU and BCSM. Different operating modes are possible for the PSIO, since the loadware for asynchronous terminal tranmission and synchronous terminal transmission have been combined. The front panel of the board contains a 7-segment display, one LED and two V.24 interfaces.
Refurbished Manufacturer Part Number: S30810-Q2139-X000
The function of the PSIO is to provide a total of six V.24 interfaces having enhanced functionality and higher data rates.
Refurbished Manufacturer Part Number: S30810-Q2113-X
The QDCL-module board S30810-Q2113-X (Quad Data Communication Link) for the Hicom 350E serves as an interface between the peripheral and the central data-processor DP (DP4L or DM3L). The module board consists of two function-units:
Compatible with the following systems: Hicom 300E
{{.}}
{{{.}}}